Process statistics

Z, t and Chi-Square Tables: Standard Normal Probabilities and Critical Values

Kitstead Labs · Engineering reference · Synthetic worked example

Three reference tables for process engineers who need a probability or a critical value without a statistics package, with the definitions that let any entry be checked.

Quick answer

The three tables answer three questions.

  1. How likely is a value this far from the mean? The standard normal table gives Φ(z), the probability that a standard normal variable is at or below z. For a measurement x from a normal process with mean µ and standard deviation σ, use z = (x − µ)/σ. The probability above z is 1 − Φ(z), and by symmetry the probability below −z is the same.
  2. How wide is a confidence interval for a mean, or how large must a t statistic be? The t table gives the critical value t with the stated upper-tail probability for the degrees of freedom df; for a two-sided interval or test, use the column for half the two-sided α. With df = ∞ the t values are the normal values.
  3. How wide is a confidence interval for a standard deviation, or how large must a chi-square statistic be? The chi-square table gives χ² with the stated upper-tail probability for df. The distribution is not symmetric, so a two-sided interval needs two entries from the same row, one from each end.

Every entry below was recomputed from the distribution itself and rounded once: Φ(z) from the error function, t from the inverse of the regularized incomplete beta function, χ² from the inverse of the regularized incomplete gamma function. The derivations and the checks are described after the tables.

About the example. The twelve bath concentration titrations in the worked example are the synthetic data of the Which control chart for which data guide, reused so that the three tables can be shown on one data set the site already carries. All interval arithmetic is carried at full precision and rounded at the end.

How the three distributions are related

The standard normal distribution is the reference. If the readings of a process are normal with known mean and standard deviation, z = (x − µ)/σ is standard normal, and Φ(z) answers any probability question about x. In practice σ is rarely known. When the standard deviation is estimated from the same n readings by the sample standard deviation s, the standardized mean (x̄ − µ)/(s/√n) is no longer normal: it follows the t distribution with n − 1 degrees of freedom, which has heavier tails than the normal because s itself varies from sample to sample. As the degrees of freedom grow the t distribution approaches the normal, which is why the last row of the t table, df = ∞, repeats the normal critical values; at df = 30 the gap to the normal value is still 0.08 in the 0.025 column and 0.17 in the 0.005 column.

The chi-square distribution describes the sample variance. For n normal readings, (n − 1)s²/σ² follows the chi-square distribution with n − 1 degrees of freedom. It is bounded below by zero and skewed to the right, so a confidence interval for σ is not symmetric about s: the lower limit uses the large chi-square value from the right tail and the upper limit uses the small value from the left tail. The same distribution gives the critical values for goodness-of-fit and contingency tests, where the statistic is a sum of squared standardized deviations.

Three conventions apply to all three tables. The tail probability in a column heading is the probability above the tabulated value, the upper tail. A two-sided α is split equally between the two tails, so a 95 % two-sided interval uses the 0.025 column. And the tables are for the standardized quantity; converting to the units of the measurement is the user's arithmetic, shown in the worked example.

Standard normal density z = 1.960 0.025 → t density, df = 3 t = 3.182 0.025 → Chi-square density, df = 5 χ² = 12.833 0.025 → Each shaded tail has probability 0.025 and continues beyond the plotted range; the critical value is where it begins.
The three distributions behind the tables, each with its 0.025 upper-tail critical value.

Table 1: Standard normal cumulative probabilities Φ(z)

The six values of z that cut off the most-used upper-tail probabilities, the ones quoted in confidence intervals and tests, come first because they are what most readers look up:

Upper-tail probabilities and their z values
Upper-tail probabilityz
0.101.282
0.051.645
0.0251.960
0.012.326
0.0052.576
0.0013.090

The full table follows. Rows give the first two digits of z, columns the third. The entry is Φ(z), the area to the left of z. For negative z use Φ(−z) = 1 − Φ(z); for the probability between −z and z use 2Φ(z) − 1.

Standard normal cumulative probabilities Φ(z), z = 0.00 to 3.49
z.00.01.02.03.04.05.06.07.08.09
0.00.50000.50400.50800.51200.51600.51990.52390.52790.53190.5359
0.10.53980.54380.54780.55170.55570.55960.56360.56750.57140.5753
0.20.57930.58320.58710.59100.59480.59870.60260.60640.61030.6141
0.30.61790.62170.62550.62930.63310.63680.64060.64430.64800.6517
0.40.65540.65910.66280.66640.67000.67360.67720.68080.68440.6879
0.50.69150.69500.69850.70190.70540.70880.71230.71570.71900.7224
0.60.72570.72910.73240.73570.73890.74220.74540.74860.75170.7549
0.70.75800.76110.76420.76730.77040.77340.77640.77940.78230.7852
0.80.78810.79100.79390.79670.79950.80230.80510.80780.81060.8133
0.90.81590.81860.82120.82380.82640.82890.83150.83400.83650.8389
1.00.84130.84380.84610.84850.85080.85310.85540.85770.85990.8621
1.10.86430.86650.86860.87080.87290.87490.87700.87900.88100.8830
1.20.88490.88690.88880.89070.89250.89440.89620.89800.89970.9015
1.30.90320.90490.90660.90820.90990.91150.91310.91470.91620.9177
1.40.91920.92070.92220.92360.92510.92650.92790.92920.93060.9319
1.50.93320.93450.93570.93700.93820.93940.94060.94180.94290.9441
1.60.94520.94630.94740.94840.94950.95050.95150.95250.95350.9545
1.70.95540.95640.95730.95820.95910.95990.96080.96160.96250.9633
1.80.96410.96490.96560.96640.96710.96780.96860.96930.96990.9706
1.90.97130.97190.97260.97320.97380.97440.97500.97560.97610.9767
2.00.97720.97780.97830.97880.97930.97980.98030.98080.98120.9817
2.10.98210.98260.98300.98340.98380.98420.98460.98500.98540.9857
2.20.98610.98640.98680.98710.98750.98780.98810.98840.98870.9890
2.30.98930.98960.98980.99010.99040.99060.99090.99110.99130.9916
2.40.99180.99200.99220.99250.99270.99290.99310.99320.99340.9936
2.50.99380.99400.99410.99430.99450.99460.99480.99490.99510.9952
2.60.99530.99550.99560.99570.99590.99600.99610.99620.99630.9964
2.70.99650.99660.99670.99680.99690.99700.99710.99720.99730.9974
2.80.99740.99750.99760.99770.99770.99780.99790.99790.99800.9981
2.90.99810.99820.99820.99830.99840.99840.99850.99850.99860.9986
3.00.99870.99870.99870.99880.99880.99890.99890.99890.99900.9990
3.10.99900.99910.99910.99910.99920.99920.99920.99920.99930.9993
3.20.99930.99930.99940.99940.99940.99940.99940.99950.99950.9995
3.30.99950.99950.99950.99960.99960.99960.99960.99960.99960.9997
3.40.99970.99970.99970.99970.99970.99970.99970.99970.99970.9998

Table 2: Critical values of t

The entry is the value of t with the column's upper-tail probability for the row's degrees of freedom. For a two-sided interval or test at level α, use the column headed α/2: a 95 % two-sided interval uses the 0.025 column, a 99 % interval the 0.005 column. The row df = ∞ holds the standard normal values.

Critical values of t by degrees of freedom and upper-tail probability
df0.100.050.0250.010.005
13.0786.31412.70631.82163.657
21.8862.9204.3036.9659.925
31.6382.3533.1824.5415.841
41.5332.1322.7763.7474.604
51.4762.0152.5713.3654.032
61.4401.9432.4473.1433.707
71.4151.8952.3652.9983.499
81.3971.8602.3062.8963.355
91.3831.8332.2622.8213.250
101.3721.8122.2282.7643.169
111.3631.7962.2012.7183.106
121.3561.7822.1792.6813.055
131.3501.7712.1602.6503.012
141.3451.7612.1452.6242.977
151.3411.7532.1312.6022.947
161.3371.7462.1202.5832.921
171.3331.7402.1102.5672.898
181.3301.7342.1012.5522.878
191.3281.7292.0932.5392.861
201.3251.7252.0862.5282.845
211.3231.7212.0802.5182.831
221.3211.7172.0742.5082.819
231.3191.7142.0692.5002.807
241.3181.7112.0642.4922.797
251.3161.7082.0602.4852.787
261.3151.7062.0562.4792.779
271.3141.7032.0522.4732.771
281.3131.7012.0482.4672.763
291.3111.6992.0452.4622.756
301.3101.6972.0422.4572.750
401.3031.6842.0212.4232.704
601.2961.6712.0002.3902.660
1201.2891.6581.9802.3582.617
∞1.2821.6451.9602.3262.576

Table 3: Critical values of chi-square

The entry is the value of χ² with the column's upper-tail probability for the row's degrees of freedom. The five left-hand columns (0.995 to 0.90) hold the small values near the left tail, the five right-hand columns (0.10 to 0.005) the large values in the right tail. A 95 % two-sided interval for a variance uses the 0.975 and 0.025 columns of the same row. For df = 1 the three smallest left-tail entries are below 0.001 and show as 0.000 or 0.001 at this precision.

Critical values of chi-square by degrees of freedom and upper-tail probability
df0.9950.990.9750.950.900.100.050.0250.010.005
10.0000.0000.0010.0040.0162.7063.8415.0246.6357.879
20.0100.0200.0510.1030.2114.6055.9917.3789.21010.597
30.0720.1150.2160.3520.5846.2517.8159.34811.34512.838
40.2070.2970.4840.7111.0647.7799.48811.14313.27714.860
50.4120.5540.8311.1451.6109.23611.07012.83315.08616.750
60.6760.8721.2371.6352.20410.64512.59214.44916.81218.548
70.9891.2391.6902.1672.83312.01714.06716.01318.47520.278
81.3441.6462.1802.7333.49013.36215.50717.53520.09021.955
91.7352.0882.7003.3254.16814.68416.91919.02321.66623.589
102.1562.5583.2473.9404.86515.98718.30720.48323.20925.188
112.6033.0533.8164.5755.57817.27519.67521.92024.72526.757
123.0743.5714.4045.2266.30418.54921.02623.33726.21728.300
133.5654.1075.0095.8927.04219.81222.36224.73627.68829.819
144.0754.6605.6296.5717.79021.06423.68526.11929.14131.319
154.6015.2296.2627.2618.54722.30724.99627.48830.57832.801
165.1425.8126.9087.9629.31223.54226.29628.84532.00034.267
175.6976.4087.5648.67210.08524.76927.58730.19133.40935.718
186.2657.0158.2319.39010.86525.98928.86931.52634.80537.156
196.8447.6338.90710.11711.65127.20430.14432.85236.19138.582
207.4348.2609.59110.85112.44328.41231.41034.17037.56639.997
218.0348.89710.28311.59113.24029.61532.67135.47938.93241.401
228.6439.54210.98212.33814.04130.81333.92436.78140.28942.796
239.26010.19611.68913.09114.84832.00735.17238.07641.63844.181
249.88610.85612.40113.84815.65933.19636.41539.36442.98045.559
2510.52011.52413.12014.61116.47334.38237.65240.64644.31446.928
2611.16012.19813.84415.37917.29235.56338.88541.92345.64248.290
2711.80812.87914.57316.15118.11436.74140.11343.19546.96349.645
2812.46113.56515.30816.92818.93937.91641.33744.46148.27850.993
2913.12114.25616.04717.70819.76839.08742.55745.72249.58852.336
3013.78714.95316.79118.49320.59940.25643.77346.97950.89253.672
4020.70722.16424.43326.50929.05151.80555.75859.34263.69166.766
5027.99129.70732.35734.76437.68963.16767.50571.42076.15479.490
6035.53437.48540.48243.18846.45974.39779.08283.29888.37991.952
8051.17253.54057.15360.39164.27896.578101.879106.629112.329116.321
10067.32870.06574.22277.92982.358118.498124.342129.561135.807140.169

Where the entries come from

Φ(z) is the integral of the standard normal density from −∞ to z and equals ½[1 + erf(z/√2)], where erf is the error function; every entry of Table 1 is this expression rounded to four decimals. The t critical value with upper-tail probability p and ν degrees of freedom is the solution of P(T > t) = p for the t distribution, which can be written through the regularized incomplete beta function: if x = I⁻¹(ν/2, ½; 2p) then t = √(ν(1 − x)/x). The chi-square critical value with upper-tail probability p and ν degrees of freedom is twice the inverse of the regularized upper incomplete gamma function with parameter ν/2 at p. These are the standard definitions; a spreadsheet function such as NORM.S.DIST, T.INV.2T or CHISQ.INV.RT evaluates the same quantities and can be used to check any entry.

Published tables differ from one another only in the last digit of entries that sit close to a rounding boundary. Φ(0.74), for example, is 0.770350003 to nine decimals, and this table prints 0.7704 because the part beyond the fourth decimal is just above one half of a unit; a table that rounds a value carried to fewer digits can print 0.7703. The difference matters only when a statistic falls within one unit of the last digit of the critical value; in that case compare it with the full-precision value or a p-value instead of the table, and report that the result sits at the boundary.

Worked example: twelve titrations, three tables

The copper concentration of a plating bath is titrated once per shift. Twelve consecutive results, in g/L, are the Stream 1 data of the control chart selection guide:

48.2, 47.9, 48.5, 48.1, 47.6, 48.3, 48.0, 47.8, 48.4, 48.2, 47.7, 48.1

The mean is x̄ = 48.067 g/L and the sample standard deviation, with n − 1 = 11 in the denominator, is s = 0.277 g/L. The standard error of the mean is s/√12 = 0.080 g/L.

Table 1: how rare is a point beyond the 3σ control limits? A Shewhart chart places its limits three standard deviations from the centre line. From Table 1, Φ(3.00) = 0.9987, so the probability above the upper limit is 1 − 0.9987 = 0.0013 when the process is stable and normal, and the probability outside either limit is 2 × 0.0013 = 0.0027, about one point in 370. That is the false-alarm rate the single-point rule accepts in exchange for reacting quickly to a real shift.

Table 2: a 95 % confidence interval for the mean concentration. With σ unknown and estimated by s, the interval is x̄ ± t × s/√n with df = 11. Table 2 gives t(11, 0.025) = 2.201, so the half-width is 2.201 × 0.080 = 0.176 g/L and the interval runs from 47.890 to 48.243 g/L. Had σ been treated as known and the normal value 1.960 used instead, the half-width would have been 0.157 g/L; the extra 0.019 g/L is the price of estimating σ from twelve values.

Table 3: a 95 % confidence interval for the standard deviation. The interval for σ is √((n − 1)s²/χ²upper) to √((n − 1)s²/χ²lower), where the two chi-square values come from the df = 11 row: χ²(11, 0.025) = 21.920 for the lower limit of σ and χ²(11, 0.975) = 3.816 for the upper limit. With (n − 1)s² = 0.847 (s carried at full precision), the interval is √(0.847/21.920) = 0.197 g/L to √(0.847/3.816) = 0.471 g/L. The interval is far from symmetric about s = 0.277, and it is wide: twelve values say little about a standard deviation. The control chart guide estimated the same σ from the average moving range as 0.427/1.128 = 0.379 g/L, which lies inside this interval; the two estimators use the data differently and neither is precise at n = 12.

Checking an entry by hand. t(∞, 0.025) must equal the normal value in the tail list, 1.960, and it does; χ²(1, 0.05) must equal the square of the two-sided normal value, 1.960² = 3.842, and the table gives 3.841, the difference being rounding of 1.95996 before squaring. Either check takes a minute and catches a transcription error in a spreadsheet.

Common mistakes

  1. Using a one-tail column for a two-sided question. A 95 % two-sided interval needs the 0.025 column, not 0.05. Reading the wrong column gives an interval that is too narrow and a test that rejects too often.
  2. Reading the t table with n instead of n − 1. The degrees of freedom for a mean estimated from n readings are n − 1. For small samples the two rows differ noticeably: t(11, 0.025) = 2.201 but t(12, 0.025) = 2.179.
  3. Using the normal value when σ is estimated from a small sample. With twelve readings the t value exceeds the normal value by 12 %. The difference vanishes only for large n; with n below about 30, use the t table.
  4. Building a symmetric interval for σ. The chi-square distribution is skewed, so the interval for σ is not s ± something. The lower limit uses the large chi-square value and the upper limit the small one, and the upper limit is usually much further from s than the lower.
  5. Applying the tables to data that are not normal, or not independent. The probabilities assume normal, independent readings. Readings that drift, alternate or come from a bounded quantity such as a count or a proportion need the model that fits them; the control chart selection guide covers the count cases.
  6. Trusting the last digit across tables. Different tables can disagree in the fourth decimal of Φ(z) or the third of t and χ² for entries near a rounding boundary. The disagreement changes a verdict only when the statistic lands within one unit of the last digit of the critical value; then the honest report is that the result sits at the boundary, checked against the full-precision value or a p-value, not a verdict read from one table.

Using the tools and guides with these tables

The Which control chart for which data guide supplies the twelve titrations and estimates their σ from moving ranges; the control chart constants guide lists the d₂ used in that estimate. The Cpk vs Ppk guide and the Process Capability Calculator turn a σ estimate into capability indices, and Table 1 is what links an index to a tail probability once the process is shown to be normal and stable. Cpk confidence intervals and sample size puts confidence intervals around those indices with the same z and chi-square distributions. Tolerance intervals for normal data uses the same tables for an interval that holds a stated proportion of the individual readings. The split-lot analysis guide uses the t distribution in the Welch test that compares two process conditions. The DPMO and Sigma Level Calculator uses the same normal tail as Table 1 in the other direction: it turns a defect rate into Z and a sigma level, or a sigma level back into DPMO. Sigma level and the 1.5σ shift explains the 1.5σ shift that the sigma level includes.

Sources and further reading