PROCESS
Attribute Control Chart Calculator (p, np, c, u)
Paste defective counts or defect counts per sample to get the p, np, c or u chart centre line and 3σ control limits, per-sample limits when the sample size varies, and the samples that fall outside them.
Open the attribute chart calculator
PROCESS
I-MR Control Chart Calculator (Individuals and Moving Range)
Paste individual readings in order to get the I and MR chart centre lines and control limits, and the points that fall outside them.
Open the I-MR chart calculator
PROCESS
Plating Rate and Efficiency Calculator (Thickness vs Time)
Fit measured copper thickness against plating time to get the deposition rate, the real current efficiency and the time to a target thickness.
Open the Plating Rate calculator
PROCESS
Process Capability Calculator (Cp, Cpk, Pp, Ppk)
Paste measurements in collection order to get Cp, Cpk, Pp and Ppk with within and overall standard deviations.
Open the Process Capability calculator
PROCESS
Subgroup Control Chart Calculator (X̄-R and X̄-s)
Paste subgrouped measurements, one subgroup per line, to get the X̄ chart and the R or s chart centre lines and control limits from the control chart constants, with the subgroups that fall outside them.
Open the subgroup chart calculator
QUALITY
AQL Sampling Plan (ANSI/ASQ Z1.4)
Find sample size, accept and reject numbers for normal, tightened and reduced single sampling.
Open the AQL calculator
QUALITY
Attribute Agreement Analysis (Kappa)
Compare two inspectors' pass/fail judgments with each other and with a reference: agreement percentages, Cohen's kappa and the direction of the misses.
Open the Attribute Agreement calculator
QUALITY
DPMO and Sigma Level Calculator
Convert defect counts, DPMO, yield and sigma level into each other, with and without the 1.5σ shift.
Open the DPMO calculator
QUALITY
Gauge R&R (ANOVA)
Calculate %GRR, %Tolerance and ndc from a crossed gauge study with the ANOVA method.
Open the Gauge R&R calculator
RELIABILITY
Acceleration Factor Calculator (Arrhenius, Peck, Coffin-Manson)
Convert a temperature, humidity or thermal-cycling stress condition into an acceleration factor and the equivalent duration at the use condition, with the Arrhenius, Peck or Coffin-Manson model.
Open the acceleration factor calculator
RELIABILITY
Success-Run Sample Size (Zero-Failure Test)
Find how many units must pass a zero-failure test to demonstrate a reliability at a given confidence, or the reliability a sample proves.
Open the success-run calculator
RELIABILITY
Weibull Analysis Calculator (Shape, Scale, B10 Life)
Paste failure times and suspensions to fit a two-parameter Weibull distribution by maximum likelihood and by rank regression: shape β, scale η, B10 life, MTTF and a Weibull probability plot.
Open the Weibull calculator
PRODUCTION
OEE Calculator (Equipment States)
Calculate OEE from six equipment states, with availability, performance and quality.
Open the OEE calculator
GENERAL
Engineering Unit Converter
Convert ppm, mil, Å, sccm, Torr, ASD and µm/min.
Open the unit converter