Process statistics
Tolerance Intervals for Normal Data: What 95/95 Means for Measurements and How It Differs from a Confidence Interval
A worked comparison for engineers who have measurements, a specification limit, and a requirement written as a coverage and a confidence.
Quick answer
A tolerance interval is a range, computed from a sample, that contains at least a stated proportion p of the population with a stated confidence C [T1]. A confidence interval is about a parameter such as the mean; a tolerance interval is about individual units. "95/95" means p = 95 % and C = 95 %.
For readings from a normal distribution the limits are the sample mean plus or minus a factor times the sample standard deviation: x̄ ± k2·s for a two-sided interval, and x̄ − k1·s or x̄ + k1·s for a one-sided bound [T1]. The factors depend on n, p and C. For 20 readings and 95/95, k1 = 2.396 and k2 = 2.760; as n grows they fall toward the normal values 1.645 and 1.960, and at every finite sample size in the table on this page they are above them.
In the example on this page, 20 synthetic seal-strength readings with mean 12.135 and s = 1.195 give a one-sided 95/95 lower bound of 9.27, above the lower specification limit of 8.5, and a 99/95 lower bound of 8.20, below it. The same 20 units recorded only as pass or fail would demonstrate 86.1 % at 95 % confidence. The measurements buy the difference, and the price is the assumption that the readings are normal.
Three intervals, three questions
The statistical tables guide builds two confidence intervals from one sample: one for the mean, from the t table, and one for the standard deviation, from the chi-square table. Both answer a question about a parameter of the process. Neither says where individual units fall.
| Interval | Question it answers | As n grows |
|---|---|---|
| Confidence interval for the mean | Where is the process mean? | The width shrinks toward zero |
| Confidence interval for σ | How large is the process spread? | The width shrinks toward zero |
| Tolerance interval | Where do at least p of the individual units fall? | The ends approach µ ± z·σ; the width approaches 2z·σ, not zero |
NIST's e-Handbook draws the same line: a confidence interval covers a population parameter with a stated confidence, and a tolerance interval covers a fixed proportion of the population with a stated confidence [T1]. It also separates statistical tolerance limits from engineering tolerances: the first are computed from data, the second are set by the designer [T1]. On this page "specification limit" always means the engineering limit, and "tolerance limit" or "tolerance bound" the computed one.
A third interval is sometimes confused with both. A prediction interval for one future reading from the same normal process, x̄ ± t·s·√(1 + 1/n) with t taken at n − 1 degrees of freedom, contains the next single reading with the stated confidence; it is the case m = 1 of the formula NIST's Dataplot manual gives for the mean of m new observations [T3]. It makes no claim about a proportion of all future units. For the example below the 95 % prediction interval is 9.57 to 14.70, narrower than the 95/95 tolerance interval from the same readings. This guide does not use it further.
Why x̄ ± 2s is not a 95 % interval
If µ and σ were known, 95 % of a normal population would lie within µ ± 1.960σ, and 95 % would lie above µ − 1.645σ. The tempting shortcut is to put x̄ and s in their place. The result is an interval that contains 95 % of the population only if x̄ and s happen to land favorably.
For 20 normal readings, x̄ ± 1.960·s contains at least 95 % of the population in 40.3 % of samples, and x̄ − 1.645·s lies below the true 5th percentile in 47.0 % of samples (calculation on this page, with the z values carried at full precision). For the sample sizes in the table below, 5 to 100, the two figures run from 33 % to 45 % and from 43 % to 49 %. The shortcut has a confidence below one half at each of those sizes. A tolerance factor is the multiplier that raises that confidence to the stated C.
The k factors
One-sided. The exact factor comes from the non-central t distribution; NIST gives it as [T1]:
k1 = t(C; n − 1, δ) / √n, with δ = z(p)·√n
where z(p) is the standard normal value with probability p below it and t(C; n − 1, δ) is the value of a non-central t distribution with n − 1 degrees of freedom and non-centrality δ that has probability C below it. Minitab's documentation describes the same method for its exact one-sided bounds [T2]. NIST notes that this inverse is missing from many spreadsheet and statistics programs and may lose accuracy for large samples [T1], and gives an approximation, credited to Natrella, that needs only normal values [T1]:
k1 ≈ (z(p) + √(z(p)² − a·b)) / a, with a = 1 − z(C)²/(2(n − 1)) and b = z(p)² − z(C)²/n
Two-sided. NIST gives Howe's approximation [T1]:
k2 ≈ z((1 + p)/2)·√(ν·(1 + 1/n) / χ²(1 − C, ν))
Here ν is the degrees of freedom of s, n − 1 when the mean and the standard deviation come from the same sample, and χ²(1 − C, ν) is the chi-square value that is exceeded with probability C: the small value from the left tail [T1]. In the chi-square table of the statistical tables guide, which is indexed by upper-tail probability, it is the entry in the 0.95 column for C = 95 %. The exact two-sided factor has no closed form; Minitab's documentation describes it as the solution of an equation that it evaluates by numerical integration [T2].
Notation. NIST writes the confidence level as α [T1]; Minitab writes it as 1 − α and the coverage as P [T2]. This page uses C for the confidence level and p for the coverage, so that C matches the confidence level of the success-run guide and p plays the part of its reliability R.
How good the approximations are. The exact factors on this page were computed by numerical integration of the definitions and checked against the values NIST prints: for n = 43, p = 0.90 and C = 0.99 the page gives k2 = 2.217 by Howe's formula, k1 = 1.8752 by Natrella's and k1 = 1.8740 by the non-central t [T1], and the same calculation reproduces all three. For 95/95 and the sample sizes in the table below, an interval built with Howe's k2 has an actual confidence between 94.8 % and 95.1 %, and a bound built with Natrella's k1 between 94.6 % and 94.9 % (calculation on this page). Those errors in confidence are small. The factor itself can be much further off for a small sample at other settings: NIST's own example for n = 6, p = 0.90 and C = 0.99 gives 5.2808 by Natrella's formula against 4.4111 by the non-central t [T1], about 20 % larger, so a bound built with it is wider than the requirement needs; its actual confidence is 99.6 %, not 99 % (calculation on this page). NIST advises that the methods differ noticeably for small samples, which it puts at about 10 or fewer [T1].
A table of factors
Exact one-sided factors k1 for three common requirements, and the two-sided factor k2 for 95/95 by the exact calculation and by Howe's approximation (calculation on this page; ν = n − 1).
| n | k1, 90/90 | k1, 95/95 | k1, 99/95 | k2, 95/95 exact | k2, 95/95 Howe |
|---|---|---|---|---|---|
| 5 | 2.742 | 4.203 | 5.741 | 5.077 | 5.094 |
| 10 | 2.066 | 2.911 | 3.981 | 3.393 | 3.382 |
| 15 | 1.867 | 2.566 | 3.520 | 2.965 | 2.955 |
| 20 | 1.765 | 2.396 | 3.295 | 2.760 | 2.752 |
| 25 | 1.702 | 2.292 | 3.158 | 2.638 | 2.631 |
| 30 | 1.657 | 2.220 | 3.064 | 2.555 | 2.550 |
| 40 | 1.598 | 2.125 | 2.941 | 2.448 | 2.445 |
| 50 | 1.559 | 2.065 | 2.862 | 2.382 | 2.379 |
| 60 | 1.532 | 2.022 | 2.807 | 2.335 | 2.333 |
| 80 | 1.495 | 1.964 | 2.733 | 2.274 | 2.272 |
| 100 | 1.470 | 1.927 | 2.684 | 2.234 | 2.233 |
| ∞ | 1.282 | 1.645 | 2.326 | 1.960 | 1.960 |
The last row holds the normal values z(p) and z((1 + p)/2): what the factor would be if µ and σ were known. The distance between a row and the last row is the cost of estimating them from n readings. At n = 100 the 95/95 one-sided factor is still 17 % above 1.645.
Worked example: 20 seal-strength readings against a lower limit
About the example. The product, the limit and the readings are synthetic. The readings were drawn from a normal distribution with mean 12.0 and standard deviation 1.2 and rounded to 0.1, so the true answers are known: 0.18 % of the population lies below the limit.
A pouch seal must have a peel strength of at least 8.5 N/15 mm. Twenty pouches from a stable process are tested, one reading each, in collection order:
13.1, 13.4, 14.0, 11.4, 13.1, 9.7, 13.1, 12.2, 13.1, 11.3, 10.2, 12.3, 12.4, 11.0, 11.6, 13.1, 12.4, 10.1, 12.9, 12.3
All 20 pass. The requirement is that at least 95 % of pouches meet the limit, demonstrated with 95 % confidence.
Step 1: mean, standard deviation and stability. Pasting the readings into the Process Capability Calculator with LSL 8.5 and no USL gives mean 12.1350, s (overall) 1.1953 and Ppk 1.014. It also reports a moving-range Cpk of 0.902, which is not used here. The I-MR Control Chart Calculator shows no reading and no moving range outside its limits.
Step 2: the two confidence intervals. With n = 20 the degrees of freedom are 19. The t table gives 2.093 in the 0.025 column, so the 95 % confidence interval for the mean is 12.135 ± 2.093 × 1.1953/√20 = 12.135 ± 0.559, or 11.58 to 12.69. The chi-square table gives 32.852 and 8.907 in the 0.025 and 0.975 columns, and (n − 1)s² = 27.15, so the 95 % confidence interval for σ is √(27.15/32.852) = 0.909 to √(27.15/8.907) = 1.746.
Step 3: the two-sided 95/95 tolerance interval. Howe's formula needs z(0.975) = 1.960 and the 0.95 column of the chi-square table at 19 degrees of freedom, 10.117:
k2 ≈ 1.960 × √(19 × 1.05 / 10.117) = 1.960 × 1.4043 = 2.752
The interval is 12.135 ± 2.752 × 1.1953, or 8.85 to 15.42. With the exact factor 2.760 it is 8.84 to 15.43. Either way it is nearly six times as wide as the confidence interval for the mean, and it is wider than the plug-in interval 12.135 ± 1.960 × 1.1953, which runs from 9.79 to 14.48.
Step 4: the one-sided 95/95 lower bound. The requirement has only a lower limit, so the one-sided bound is the one to compare with it. From the table, k1 = 2.396:
12.135 − 2.396 × 1.1953 = 9.27
The bound is above 8.5. With 95 % confidence, at least 95 % of pouches have a peel strength above 9.27, and therefore above the limit: the requirement is met. Natrella's approximation gives k1 = 2.378 and a bound of 9.29.
Step 5: a tighter requirement. For 99 % coverage at 95 % confidence the factor is 3.295, and the bound is 12.135 − 3.295 × 1.1953 = 8.20. That is below 8.5, so these 20 readings do not demonstrate 99 %. The process behind them has 99.82 % of its output above the limit; the sample is too small to show it. The largest coverage these readings demonstrate at 95 % confidence is 98.4 %, the value of p at which k1 equals the observed distance to the limit, (12.135 − 8.5)/1.1953 = 3.04 standard deviations. If the mean and standard deviation stayed where they are, the 99/95 bound would reach the limit at 32 readings; the estimates will move as readings are added, so 32 is an indication, not a plan.
The same test written as a Ppk requirement
The comparison in Step 4 can be rearranged. The bound x̄ − k1·s is at or above the lower specification limit exactly when (x̄ − LSL)/s is at least k1, and (x̄ − LSL)/(3s) is the one-sided Ppk. So, for a single specification limit:
the one-sided tolerance bound clears the limit when Ppk ≥ k1/3.
For 20 readings that is Ppk ≥ 0.799 for 95/95 and Ppk ≥ 1.098 for 99/95; the example's Ppk of 1.014 sits between them, which is the result of Steps 4 and 5 in other units. The threshold depends on n: the same Ppk of 1.014 from 100 readings would clear the 99/95 threshold of 2.684/3 = 0.895.
Two cautions. The factors assume the ordinary sample standard deviation s with n − 1 degrees of freedom, so the index to compare is Ppk, not the moving-range Cpk; Cpk confidence intervals and sample size explains why the moving-range estimate carries fewer degrees of freedom. And that guide answers a different question, how far the true index may lie from the estimate, with an approximation for specifications that may have two limits. The two pages share a distribution, not a procedure; the tolerance factor here should not be used to recompute the intervals there.
Measurements against pass or fail
The success-run guide covers the attribute version of the same requirement: n units, all passing, demonstrate reliability R with confidence C when R^n ≤ 1 − C. It notes that when a measurement is available, a variables test demonstrates the same reliability with far fewer units. The example shows the size of that difference and what it rests on.
| Pass or fail only | Measurements, normal model | |
|---|---|---|
| What 20 passing units demonstrate at 95 % confidence | 86.1 % | 98.4 % in this sample |
| Units needed for 95/95 | 59, all passing | No fixed number: any n of 2 or more, if x̄ is at least k1·s from the limit; 20 here |
| Units needed for 99/95 | 299, all passing | 32, if x̄ and s stayed as observed |
| Assumes | Independent units from one population | The same, and a normal distribution out to the limit |
The measurement plan is smaller because it uses how far each reading is from the limit, not only which side it is on. It pays for that in two ways. First, the result depends on the margin and on the luck of the sample. The example process, with 99.82 % of its output conforming, passes the 95/95 test with 20 readings in 89 % of samples and the 99/95 test in 29 %. A process whose mean is 2 standard deviations from the limit has 97.7 % of its output conforming, more than the 95 % required, yet passes the 95/95 test with 20 readings in only 21 % of samples (calculation on this page). Second, the claim is about a tail that the sample does not reach. The lowest of the 20 readings is 9.7; the statement that 95 % of pouches exceed 9.27 comes from the normal model, not from readings near 9.27.
What the interval assumes
A normal distribution. The factors are derived for normal readings [T1]. Twenty readings can reveal a gross departure, such as a strongly skewed histogram, but they cannot confirm the shape of the lower 1 % of the distribution. The higher the coverage claimed, the further the claim extends beyond the data. Process capability for non-normal data discusses skewed readings.
One stable population. The readings must be independent and come from a process that is not drifting. Units from a single lot, cavity or shift describe that lot, cavity or shift. Check the order of the readings on an I-MR chart before computing the interval, as in Step 1.
The standard deviation and its degrees of freedom. The table assumes s from the same n readings, ν = n − 1. NIST notes that Howe's formula allows other values of ν [T1]; the one-sided formulas above do not, as written.
Sampling error only. The confidence C covers the chance of an unlucky sample. It does not cover measurement error, a change in material, or a test condition that differs from use.
Common mistakes
- Using x̄ ± 2s or x̄ ± 3s as if µ and σ were known. With 20 readings, x̄ ± 1.960·s contains 95 % of the population in about 40 % of samples. Use the factor for the n, p and C in hand.
- Quoting the confidence interval for the mean as the range of the product. In the example the mean lies between 11.58 and 12.69 with 95 % confidence, while 95 % of pouches lie between 8.84 and 15.43 with the same confidence. The first interval says nothing about a single pouch.
- Mixing one-sided and two-sided factors. A two-sided interval claims that 95 % lie between its two ends; a one-sided bound claims that 95 % lie above it. In the example the two-sided lower end is 8.84 and the one-sided bound is 9.27. For a single specification limit use k1; a k1 bound on each side of a two-sided specification is not a two-sided 95/95 interval. State which one a "95/95" refers to.
- Reading p as an estimate of the conforming fraction. A demonstrated 98.4 % is a lower bound at 95 % confidence. The process in the example is at 99.82 %.
- Using the factors with a within-subgroup or moving-range sigma. They are derived for s with n − 1 degrees of freedom.
- Trusting the normal model further than the data reach. A 99.9 % coverage claim from 20 readings is a statement about the fitted curve.
- Treating a tolerance limit as a specification. A computed limit describes what the process delivers; whether that is acceptable is decided by the engineering limit.
Using the tools and guides
The Process Capability Calculator gives the mean, s and, for a single limit, the one-sided Ppk to compare with k1/3; it does not compute tolerance factors. The I-MR Control Chart Calculator checks stability first. The statistical tables guide supplies the z and chi-square values for Howe's formula and the t and chi-square values for the two confidence intervals. The Success-Run Sample Size calculator gives the attribute sample sizes quoted above. The non-central t value for an exact one-sided factor needs statistical software; the table on this page covers the common cases.
Sources and further reading
- [T1] NIST/SEMATECH e-Handbook of Statistical Methods, Section 7.2.6.3, Tolerance intervals for a normal distribution — definition, the distinction from confidence intervals and engineering tolerances, Howe's two-sided factor, Natrella's one-sided approximation, the non-central t method and worked values.
- [T2] Minitab Support, Methods and formulas for Tolerance Intervals (Normal Distribution) — exact one-sided factor from the non-central t distribution, exact two-sided factor by numerical solution, notation.
- [T3] NIST Dataplot Reference Manual, PREDICTION LIMITS — prediction interval for the mean of m new observations, which includes a single future observation.
- Referenced by name; not reproduced here: Howe, W. G. (1969), "Two-sided Tolerance Limits for Normal Populations - Some Improvements", Journal of the American Statistical Association 64, 610–620, and Natrella, M. G. (1963), Experimental Statistics, NBS Handbook 91, both as credited by NIST; Krishnamoorthy, K. and Mathew, T. (2009), Statistical Tolerance Regions: Theory, Applications, and Computation, Wiley, as credited by Minitab; Hahn, G. J. and Meeker, W. Q. (1991), Statistical Intervals: A Guide for Practitioners, Wiley; ISO 16269-6.
- Kitstead Labs guides: Statistical tables, Cpk confidence intervals and sample size, Success-run sample size, Process capability for non-normal data.
This guide explains the arithmetic of normal tolerance intervals. It does not replace the sampling or validation procedure your customer or standard specifies, and it does not cover non-parametric tolerance intervals, other distributions, or acceptance sampling by variables.