Acceleration Factor Calculator (Arrhenius, Peck, Coffin-Manson)

Enter the use and stress conditions and get the acceleration factor and the equivalent duration at the use condition for a temperature, temperature-humidity or thermal-cycling test. Every value is entered by you; the tool adds no data of its own.

01Inputs

From your own failure-mechanism data or the source you qualify against; the tool does not supply typical values.

Temperature at the use or field condition.

Temperature during the accelerated test.

Relative humidity at the use condition, in percent.

Relative humidity during the test, in percent.

Exponent on the humidity ratio; take it from the same source as Ea.

Peak-to-peak temperature swing of one cycle at the use condition.

Peak-to-peak temperature swing of one test cycle.

Exponent on the temperature-range ratio; take it from your own cycling data or the source you qualify against.

Optional. Enter the test length to get the equivalent duration at the use condition.

02Result

03Method

Use this tool when you have an accelerated test condition and need the factor that relates it to the use condition, or the use-condition time that a test of a given length represents. It evaluates three ratio-form models from the numbers you give it: the Arrhenius model for a temperature stress, the Peck model for combined temperature and humidity, and the Coffin-Manson model for thermal cycling. It does not choose the model, the activation energy or the exponents for you; those come from the failure mechanism and from the standard or data you qualify against, and the result is only as good as they are.

AHow it is calculated
  • T(K) = T(°C) + 273.15.
  • k = 1.380649 × 10−23 J/K ÷ 1.602176634 × 10−19 C = 8.617333262… × 10−5 eV/K; both SI constants are exact (CODATA 2022).
  • Arrhenius: AF = exp[(Ea/k)(1/Tuse − 1/Tstress)].
  • Peck: AF = (RHstress/RHuse)n · exp[(Ea/k)(1/Tuse − 1/Tstress)]; RH in percent (the ratio is unit-free).
  • Coffin-Manson: AF = (ΔTstress/ΔTuse)m; ΔT in °C (kelvin differences are the same numbers).
  • Equivalent duration at the use condition = duration at the stress condition × AF.

Worked example: with Ea = 0.7 eV, a 125 °C test (398.15 K) against a 55 °C use condition (328.15 K) gives an exponent of 4.3522 and AF = 77.65, so 1000 hours at 125 °C correspond to 77,650 hours at 55 °C.

Peck: Ea 0.79 eV, n 2.7, 25 °C at 60 % RH against 85 °C at 85 % RH gives a temperature factor of 172.6, a humidity factor of 2.561 and AF = 442.1.

Coffin-Manson: ΔT 165 °C, the −40 to 125 °C cycle, against ΔT 110 °C, a −10 to 100 °C cycle, with m = 2 gives AF = 2.25, so 1000 test cycles correspond to 2,250 cycles at the use condition.

BScope and limitations
  • Ratio form only. Each model is used as the ratio of two lifetimes, so the pre-exponential constant cancels and is not asked for; the tool gives a factor, never a lifetime. To turn a factor into a predicted life you also need a measured or demonstrated life at one of the two conditions.
  • The parameters are yours. Activation energies, the humidity exponent and the cycling exponent differ by failure mechanism, material and package, and published ranges are wide; the tool prints no typical values and takes whatever you enter. Use the values from the standard your customer specifies or from your own data, and record where they came from.
  • One mechanism at a time. An acceleration factor belongs to one failure mechanism; a test that activates a different mechanism than the field does (for example melting a solder joint at a temperature the field never reaches) is not accelerated by this factor, it is a different test.
  • Coffin-Manson is reduced to its temperature-range term. The fuller form used for solder-joint fatigue adds a cycling-frequency term and an Arrhenius term at the maximum temperature; the tool omits both, so it compares only the swing of one cycle against another and assumes the same dwell times and ramp rates.
  • Peck's model is used in its ratio form with relative humidity in percent; the exponent n applies to the humidity ratio and is unrelated to the activation energy. A factor is only meaningful where the mechanism is the one the model was fitted to (moisture-driven corrosion and delamination), not for every humidity test.
  • A factor below 1 means the entered stress is milder than the use condition under that model; the tool shows it rather than refusing, since the inverse question (how much slower does a lower temperature run) is sometimes the one being asked.
  • The factor says nothing about how many units to test or what a passed test demonstrates; the Success-Run Sample Size tool and the Success-run sample size guide answer that, and the Accelerated life testing guide shows how the two are used together.
CCommon mistakes
  1. Using °C in the exponent. The Arrhenius and Peck exponents need absolute temperature; 1/55 − 1/125 and 1/328.15 − 1/398.15 differ by a factor of about 19. The tool converts for you, but a spreadsheet will not.
  2. Reading a typical activation energy as a property of the test. Ea belongs to the failure mechanism, not to the chamber; from a 55 °C use condition the same 125 °C test accelerates a 0.3 eV mechanism by 6.5 and a 1.0 eV mechanism by 501.
  3. Multiplying factors for the same stress. Peck's humidity term and the Arrhenius temperature term multiply because they are different stresses; two temperature models for the same mechanism do not stack.
  4. Treating the equivalent duration as a demonstrated life. 1000 test hours at a factor of 77.65 "correspond to" 77,650 use hours only for the units that survive and only under the model; the demonstrated reliability still comes from how many units passed, which is the success-run question.
  5. Entering the temperature range as the maximum temperature. Coffin-Manson uses the swing of a cycle (−40 to 125 °C is ΔT = 165 °C), not the upper limit.
  6. Qualifying a 0.3 eV mechanism with a 0.7 eV factor because that was the value in last year's report. A higher Ea gives a larger factor and a shorter test; if the mechanism is the lower-Ea one, the test is simply too short.

Further reading

  • NIST/SEMATECH e-Handbook of Statistical Methods, Sections 8.1.5.1 (Arrhenius) and 8.1.5.3 (other models, including temperature-humidity and Coffin-Manson forms).
  • Peck, D. S., "Comprehensive Model for Humidity Testing Correlation", Proceedings of the 24th International Reliability Physics Symposium (IRPS), 1986, pp. 44–50.
  • Nelson, W. B., Accelerated Testing: Statistical Models, Test Plans, and Data Analyses, Wiley, 1990. Chapter 2 (models).