Accelerated Life Testing: Arrhenius, Peck and Coffin-Manson Acceleration Factors Explained

Kitstead Labs · Engineering reference · Synthetic worked example

A qualification example for reliability and validation engineers who have to say what 1,000 hours in a chamber mean in the field.

Quick answer

An accelerated life test runs units at a harsher condition than the field so that a failure mechanism that would take years shows up in weeks. The acceleration factor AF is the ratio of the time to failure at the use condition to the time to failure at the stress condition, for one failure mechanism, under one model:

AF = t_use / t_stress

Three models cover most qualification plans. For a temperature stress, the Arrhenius model gives AF = exp[(Ea/k)(1/T_use − 1/T_stress)] with the temperatures in kelvin, Ea the activation energy of the mechanism in electronvolts and k the Boltzmann constant, 8.617 × 10⁻⁵ eV/K. For temperature with humidity, Peck's model multiplies that by a humidity ratio raised to a power, (RH_stress/RH_use)^n. For thermal cycling, the Coffin-Manson relation compares the temperature swing of a cycle, AF = (ΔT_stress/ΔT_use)^m.

With Ea = 0.7 eV, a 1,000-hour test at 125 °C stands for about 77,600 hours at 55 °C, close to nine years. With Ea = 0.3 eV the same test stands for 6,460 hours, under a year. The model is the easy part; the parameter is the whole question. The Acceleration Factor Calculator evaluates all three models from the numbers you give it.

This guide explains where the ratio form comes from, works one fictional qualification case through the three models, shows how the factor combines with a success-run sample size, and lists what the models assume.

About the example. The product, test plan and parameter values are fictional and chosen for arithmetic clarity. The activation energies and exponents used here are inputs to the example, not recommendations; the values for your product come from your failure-mechanism data or from the standard you qualify against.

What an acceleration factor is

Every acceleration model starts as a formula for the time to failure, t_f = A · G(stress), where A is a constant that depends on the material, the geometry and the definition of failure, and G describes how the stress shortens the life. The constant A is rarely known. The ratio of two lifetimes at two stress levels does not need it:

AF = t_f(use) / t_f(stress) = G(use) / G(stress)

That cancellation is why acceleration factors can be used without ever predicting a lifetime. It also fixes what a factor can and cannot do. Multiplying the test duration by AF gives the use-condition duration that the test represents; it does not say whether the units will survive it. That answer comes from how many units were tested and how many passed, which is the success-run question treated at the end of this guide.

A factor belongs to one failure mechanism. A temperature test that accelerates electromigration by a factor of 80 says nothing about a solder-joint fatigue mechanism that temperature alone does not drive, and a test hot enough to trigger a mechanism the field never sees is a different test, not a faster one.

The three models

Arrhenius: temperature

The Arrhenius relation describes mechanisms whose rate rises exponentially with temperature: diffusion, oxidation, intermetallic growth, many chemical and electrochemical processes. In ratio form:

AF = exp[ (Ea / k) · (1/T_use − 1/T_stress) ]

T_use and T_stress are absolute temperatures, °C + 273.15. Ea, the activation energy, is the only parameter. k is the Boltzmann constant; in electronvolt units it is the quotient of two exactly defined SI constants, 1.380649 × 10⁻²³ J/K divided by 1.602176634 × 10⁻¹⁹ C, which is 8.617333262… × 10⁻⁵ eV/K. The factor Ea/k is often quoted as Ea × 11,605 K.

Two features of the formula matter in practice. The factor depends on the difference of reciprocal temperatures, so the same 70-degree step gives a much larger factor at low temperatures than at high ones. And Ea sits in the exponent, so an error in Ea is an exponential error in the factor: at 55 °C against 125 °C, moving Ea from 0.3 to 1.0 eV moves the factor from 6.5 to 501.

Peck: temperature and humidity

For moisture-driven mechanisms in plastic-encapsulated parts, corrosion of metallisation and delamination above all, Peck's model multiplies an Arrhenius temperature term by a humidity term:

AF = (RH_stress / RH_use)^n · exp[ (Ea / k) · (1/T_use − 1/T_stress) ]

RH is relative humidity in percent; the ratio is unit-free. The exponent n and the activation energy are fitted together for a mechanism and should be taken from the same source. The two terms multiply because they are different stresses acting on the same mechanism; they are not two estimates of the same thing. The usual stress condition is 85 °C at 85 % RH, often called 85/85.

Coffin-Manson: thermal cycling

Cracking of solder joints, wire bonds and interconnects under repeated expansion and contraction is driven by the strain range of each cycle, which for a given assembly is set by the temperature swing. The Coffin-Manson relation in its simplest ratio form is:

AF = (ΔT_stress / ΔT_use)^m

ΔT is the peak-to-peak swing of one cycle, so a −40 to 125 °C chamber cycle has ΔT = 165 °C, and a product that sees −10 to 100 °C in the field has ΔT = 110 °C. The factor is a ratio of cycles, not of hours, and the exponent m carries all the material behaviour. Fuller forms used for solder-joint fatigue add a cycling-frequency term and an Arrhenius term at the maximum temperature; the ratio above omits both, which means it assumes similar dwell times and ramp rates in the chamber and the field.

Worked example: qualifying a packaged device

A packaged device must survive ten years in an enclosure whose internal temperature is taken as a steady 55 °C, with 60 % RH, and which cycles once a day between −10 and 100 °C. Ten years is 87,600 hours and about 3,650 cycles. The qualification plan has three tests: a high-temperature operating life test at 125 °C, a temperature-humidity test at 85 °C and 85 % RH, and temperature cycling between −40 and 125 °C. The engineer's job is to say how long each test must run to represent ten years.

Temperature: what 1,000 hours at 125 °C mean

The failure mechanism of concern for the life test has an activation energy of 0.7 eV in the data the plan is based on. In kelvin the two temperatures are 328.15 K and 398.15 K, and

(Ea / k)(1/T_use − 1/T_stress) = (0.7 / 8.617 × 10⁻⁵) × (1/328.15 − 1/398.15) = 4.352

AF = exp(4.352) = 77.65

So 1,000 hours at 125 °C represent 77,650 hours at 55 °C, which is 8.9 years and falls short of the ten-year target. To represent 87,600 use hours the test must run 87,600 / 77.65 = 1,128.2 hours, so the plan is changed to 1,129 hours.

Then the sensitivity check that every plan should contain. If the mechanism that actually limits life has Ea = 0.3 eV, the factor is 6.457 and the 1,129-hour test represents 7,290 hours, ten months. Demonstrating ten years for that mechanism would take 13,566 hours at 125 °C, over a year and a half. The plan cannot be judged without knowing which mechanism it is meant to accelerate.

Temperature and humidity: 85/85

For the humidity test the plan uses Ea = 0.79 eV and n = 2.7. The temperature term from 25 °C to 85 °C (the humidity test is referenced to a 25 °C, 60 % RH use condition in this plan) is exp(5.151) = 172.6; the humidity term is (85/60)^2.7 = 2.561; their product is AF = 442.1. A 1,000-hour 85/85 test represents 442,100 use hours, about fifty years, and ten years are covered by 198 hours. Humidity tests are usually run far longer than this arithmetic requires, because the exponent n and the activation energy are among the least certain parameters in reliability work and because the mechanism has an incubation period before moisture reaches the die.

Thermal cycling

With m = 2 for the assembly's solder joints, the −40 to 125 °C chamber cycle (ΔT = 165 °C) against the −10 to 100 °C field cycle (ΔT = 110 °C) gives

AF = (165 / 110)² = 2.25

so 1,000 chamber cycles represent 2,250 field cycles, about six years at one cycle a day, and the ten-year target of 3,650 field cycles needs 1,623 chamber cycles. If m is 2.5 instead, the factor is 2.756 and the same ten years need 1,325 cycles. The thermal-cycling factor is small compared with the temperature factors because the stress ratio is a modest 1.5 raised to a modest power; cycling tests are long for that reason.

1 10 100 1,000 10,000 55 75 85 105 125 150 stress temperature (°C), use temperature 55 °C acceleration factor (log scale) 0.3 eV 0.5 eV 0.7 eV 1.0 eV 125 °C, 0.7 eV: AF = 77.6
All four curves start at 1 at the use temperature and rise exponentially, but their spacing is the story: at 125 °C the factors span 6.5 to 501 depending only on Ea. The activation energy, not the chamber temperature, is the number that decides how long a test must run.

Acceleration factors for a 55 °C use temperature

The table gives the Arrhenius factor for the stress temperatures most often used in operating-life tests, at a use temperature of 55 °C. It is computed from the formula above with 273.15 and the CODATA value of k; the calculator reproduces every cell.

Arrhenius acceleration factor from 55 °C, by activation energy and stress temperature
Ea85 °C105 °C125 °C150 °C
0.3 eV2.4324.0666.45710.82
0.5 eV4.39810.3622.3952.97
0.7 eV7.95326.3977.65259.2
1.0 eV19.34107.3501.42,805

Reading down a column is the sensitivity check of the worked example; reading across a row shows what a hotter chamber buys. Raising the stress from 125 to 150 °C triples the 0.7 eV factor, but only if the mechanism survives the change of temperature unchanged; above a material's glass transition or a solder's melting point it does not.

Coffin-Manson acceleration factor for a −40 to 125 °C chamber cycle (ΔT = 165 °C), by field swing and exponent
mΔT_use = 60 °CΔT_use = 80 °CΔT_use = 110 °C
1.54.5602.9621.837
27.5634.2542.250
2.512.546.1092.756
320.808.7743.375
1 5 10 15 20 25 40 60 80 110 140 165 field temperature swing ΔT (°C), chamber swing 165 °C acceleration factor m = 1.5 m = 2 m = 2.5 m = 3 ΔT 110 °C, m = 2: AF = 2.25
Every curve reaches 1 where the field swing equals the chamber swing. A product with a gentle field cycle is strongly accelerated by the chamber; a product that already sees most of the chamber swing in the field is barely accelerated at all, and its cycling test is long whatever the exponent.

Combining the factor with a sample size

The factor converts hours; it does not demonstrate reliability. The demonstration comes from the number of units that pass. The success-run formula says that 22 units passing a test with no failures demonstrate a reliability of at least 90 % at 90 % confidence for whatever the test represents. Putting the two together, 22 units passing 1,129 hours at 125 °C demonstrate, at 90 % confidence, that at least 90 % of the population survives ten years at 55 °C with respect to the 0.7 eV mechanism, and under the Arrhenius model.

Each clause in that sentence is a condition, and dropping any of them overstates the result. The factor is model- and mechanism-specific; the reliability figure is a lower bound at a stated confidence; and the whole statement is only as good as the activation energy that went into it.

When the life itself is to be estimated rather than demonstrated, the Weibull analysis for engineers guide fits a life distribution to the failure times and suspensions, and the acceleration factor converts its characteristic life to the use condition.

What the models assume

The ratio form assumes that the stress changes the rate of one mechanism and nothing else: the same mechanism, the same failure definition and the same distribution shape at both conditions. Where the stress introduces a new mechanism, the model does not apply, and a test that is "too accelerated" produces failures the field will never see.

The parameters are properties of the mechanism in a specific material system, not of the test. Published activation energies for a mechanism spread over a wide range, and the exponents in Peck's and Coffin-Manson's relations are fitted values that vary with package, solder and geometry. A qualification plan should name the source of each parameter it uses.

Arrhenius assumes the rate is temperature-driven in the thermal sense; mechanisms driven by voltage, current density or mechanical stress need their own terms, which is what the general Eyring model provides. Peck's model is a fit to moisture-driven failure of plastic packages and should not be used as a generic humidity formula. Coffin-Manson in the form used here ignores dwell time, ramp rate and the mean temperature of the cycle, all of which affect solder fatigue; a chamber cycle with short dwells can show less damage per cycle than the field cycle it is meant to accelerate.

Common mistakes

  1. Using °C in the exponent. 1/55 − 1/125 and 1/328.15 − 1/398.15 differ by a factor of about 19; the model needs absolute temperature.
  2. Treating a typical activation energy as a property of the test. From a 55 °C use condition the same 125 °C chamber accelerates a 0.3 eV mechanism by 6.5 and a 1.0 eV mechanism by 501. The value belongs to the mechanism.
  3. Reading the equivalent hours as a demonstrated life. 1,129 hours "represent" ten years only for the units that passed, under the model, at the stated confidence. The demonstration is the success-run statement, not the factor.
  4. Stacking factors for the same stress. Temperature and humidity terms multiply because they are different stresses. Two temperature models for one mechanism, or a factor applied to a test already quoted in equivalent hours, double-count.
  5. Entering the chamber's upper temperature as ΔT. Coffin-Manson uses the swing of a cycle; −40 to 125 °C is 165 °C, not 125 °C.
  6. Choosing the parameter that makes the test short. A higher Ea gives a larger factor and a shorter test. If the limiting mechanism has the lower Ea, the test is simply too short, and the shortfall is invisible until the field reports it.

Using the calculator with this guide

The Acceleration Factor Calculator evaluates the three models in ratio form and, when you enter a test duration, gives the equivalent duration at the use condition. Enter Ea = 0.7 eV, 55 °C and 125 °C with 1,000 hours to reproduce the 77.65 factor and the 77,650 hours above; switch to Peck with 0.79 eV, 2.7, 25 °C at 60 % RH and 85 °C at 85 % RH for the 442.1 factor; switch to Coffin-Manson with ΔT 110 and 165 °C and m = 2 for the 2.25 factor. The tool prints no typical parameter values; the Success-Run Sample Size tool supplies the number of units.